Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0424-02424
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/20/2024 | Site Engineering | NOT REQUIRED | |||
05/20/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/09/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0424-02424 (487 E HISTORIC ST TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. The approved plans for the existing solar system (Permit: T06CM01163) shows a Xantrex GT 3.0 inverter, not the Fronius Galvo 2.0-1 inverter shown on your plans. Please verify that the correct existing inverter is listed as the Xantrex GT3.0 inverter has a higher output current. 2. The S-5-S clamp is not included in the list of S-5 products covered by the UL listing sheet. Verify and provide the S-5-S listing sheet or provide an attachment analysis by a qualified Arizona Registrant. R106.1. 3. Provide a Grounding Electrode System at the detached structure per NEC 690.47. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
04/23/2024 | PDSD Application Completeness | REVIEW COMPLETED |