Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0424-02418
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/09/2024 | Residential Building | APPROVED | |||
| 04/23/2024 | Fire New Construction | NOT REQUIRED | |||
| 05/20/2024 | Site Engineering | NOT REQUIRED | |||
| 05/15/2024 | Site Landscape | NOT REQUIRED | |||
| 05/20/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/20/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0424-02418 9289 East 29th Street – R-1 Enclose carport into garage and expand storage room (2nd Review) TRANSMITTAL DATE: May 20, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Remove the existing rear porch from the lot coverage calculation as roofed areas, open on at least one side, which provide shelter to exterior areas, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are excluded from the lot coverage calculation (UDC 6.4.3.C.1.a). 2. According to the Estes Park No. 2 subdivision plat, the size of the lot is 8,056 square feet: https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-20077&. Update the lot coverage calculation to reflect the correct lot size. 3. Verify the street perimeter yard by providing a dimension from the centerline of 29th Street to the face of curb location, as well as a dimension from the face of curb location to the street property line. Per page 8 of paving plan I-70-042, the distance from the centerline of 29th Street to the face of the curb is 22 feet, and the distance from the face of curb to the street property line is 23 feet. The street property line is also located one foot behind the edge of sidewalk: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-70-042. 4. Perimeter yards are based on a measurement from the design grade elevation to the highest point of an exterior building wall (see UDC 6.4.5-B and Figure 6.4.5-A). Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear perimeter yards are six feet or 2/3 the height of the exterior building wall, whichever is greater. Provide a dimension measured from the design grade elevation to the highest point of the proposed wall under the roof overhang to verify the above perimeter yard requirement. A Design Development Option (DDO) will be required if the height of the proposed exterior wall exceeds a height of 9’-0”. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf. Contact Georgia.Pennington@tucsonaz.gov if you have questions about the DDO process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 04/23/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |