Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0424-02319
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2024 | Residential Building | NOT REQUIRED | |||
| 05/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/14/2024 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov if you have any questions about the FUP. |
||
| 05/16/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Nathan Herrera Lead Planner PROJECT: TC-RES-0424-02192 Address: 2554 N TREAT AV TUCSON, AZ 85716 Parcel: 112-07-3970 Zoning: R-2 Existing Use: Single Family Residence Project Description: CE Violation (CE-VIO0223-01986) Abatement: Detached Carport/Storage Structure TRANSMITTAL DATE: 5/16/2024 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9 & .10. 1. COMMENT: Zoning has no comments for the carport located in the front yard of the property. Per UDC Article 6.6.3.C, carports under 400 square feet are allowed in the buildable area extending the full width of the lot between the principal building and the front street lot line. 2. COMMENT: Per UDC Article 6.6.3.C, Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. The Code Violation, CE-VIO0223-01986, references a detached storage shed located in the front yard. The storage shed is not shown on the submitted plans. The detached storage shed located in the front yard will not be able to be permitted in its current state. The following options will allow for the storage shed to be permitted in its current location: 1. A Board of Adjustment Variance process will be required to allow for the structure to be. For more information on the Variance process reach out to Mark Castro at Mark.Castro@tucsonaz.gov 2. The storage shed can be connected to the main house through a structural element that is a minimum of five feet wide and can support a twenty-pound live load. Provide a dimension from Design Grade to the top of the building. 3. COMMENT: Show the storage shed on the plans with the next submittal. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or at 520-837-4894. |
||
| 04/18/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |