Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0424-02192
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2024 | Fire New Construction | NOT REQUIRED | |||
| 05/07/2024 | Site Engineering | NOT REQUIRED | |||
| 05/08/2024 | Site Landscape | NOT REQUIRED | |||
| 05/13/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/01/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0424-02192 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Update the outdated 2012 reference on M1, P1 and E1. Provide a response letter on separate file with submitting the updated construction plan set. Remove the “for review only” note from each sheet of the approved construction plan set. Remove the overtype text from note #14 sheet S2. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Provide a Riser Diagram showing the Pima County assigned address for each meter, R319. 2. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901 or change the room name to kitchenette. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 05/13/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Nathan Herrera Lead Planner PROJECT: TC-RES-0424-02192 Address: 2756 N RICHEY BL TUCSON, AZ 85716 Parcel: 111-08-0120 Zoning: R-2 Existing Use: Single Family Residence Project Description: Attached Garage/Sleeping Quarters TRANSMITTAL DATE: 5/06/2024 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9 & .10. 1. COMMENT: Clarify the scope of work. It appears that what is being proposed above the garage is what is referred to as a “Sleeping Quarters”. In order to be considered a sleeping quarters the kitchen area is limited to having a under the counter refrigerator, wet bar (single basin) sink, and no cooking facilities. The building sections show a full-size fridge and double basin sink, these will have to change on the next submittal in order for the structure to be considered a sleeping quarters, and not an additional residential unit. 2. COMMENT: Per UDC Article 6.4.4.A, Building height is measured from Design Grade, not Finished Floor Elevation. Provide a dimension from Design Grade to the top of the building. 3. COMMENT: Per UDC Table 6.3-2.A, the required side and rear yard setbacks in the R-2 zone are the greater of 6 feet or 2/3 the height of the building wall. A dimension from Design Grade to the top of the proposed building wall. The following comments will assume an additional 6 inches from FFE to design grade. However, the required setback may changed once a dimension from Design Grade is shown. With a proposed wall height of 23 feet the required setback to the southern is 15 feet 4 inches, the proposed setback is 8 feet 8 inches. With a wall height of 17 feet 10 inches, the required setback from the eastern property to the proposed staircase is 11 feet 11 inches, the proposed setback could not be determined. Provide a dimension to the proposed staircase on the next submittal. With a wall height of 23 feet the required setback from the eastern property line to the proposed building wall is 15 feet 4 inches, the proposed setback is 8 feet 8 inches. The proposed structure encroaches into the required perimeter yard and will require the approval of a Design Development Option (DDO) before zoning can approve of this permit. The below paperwork can be filled out and submitted with the next submission. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf For more information about the DDO process contact Wyatt Berger at wyatt.berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov or at 520-837-4894 |
||
| 04/12/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |