05/14/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/14/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Provide complete roof framing information for determining Load carrying capacity for the roof structure. Show all load bearing locations. Demonstrate the ability for supporting the existing and additional dead load, and provide an engineer’s calculation, design, and seal for verifying the truss load carrying capacity. R324.4 Equipment shall be positively attached to the roof structure with a minimum of one connection per 10 sf of equipment (minimum of two connections per piece of equipment). Point loads exceeding 40 lbs shall require a structural load analysis by licensed Arizona engineer. R106.1 and R301.1.3 | ||