Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0424-02136
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/07/2024 | Site Engineering | NOT REQUIRED | |||
| 05/14/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/01/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0424-02136 (3307 N OLSEN AV Unit:UNIT 2 TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). Mechanical Review: 1. Provide whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the system and appropriate flow rate setting on the plans. 2. Provide cooling equipment sized in accordance with Manual S calculations, M1401.3. 3. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J. Electrical Review: 4. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. This may require a floor mounted receptacle outlet within 18” of the window wall, R3901.2.3. The bedroom only has two receptacles. 5. Show the over current protection device size, or main breaker, for the sub panel, E3705.5. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 05/14/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Nathan Herrera Lead Planner PROJECT: TC-RES-0424-02136 Address: 3307 N OLSEN AV Unit: 2 TUCSON, AZ 85719 Parcel: 113-06-0550 Zoning: RX-2 Existing Use: Single Family Residence Project Description: Attached Accessory Dwelling Unit/Detached Carport TRANSMITTAL DATE: 05/14/2024 This site is located in the RX-2 zone (UDC 4.7.6). A single-family residence, with an Accessory Dwelling Unit is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3. 1. COMMENT: PER UDC Article 6.4.5.C.1.b, “For carports and garages which face the street, the minimum required street perimeter yard is 20 feet…” The carport encroaches into the required setback. It appears that the proposed setback is 0 feet from the property line. A Board of Adjustment Variance process will be required to allow for the setback reduction as shown. Alternatively, if the setback for the proposed carport is 1 foot from the property line a Design Development Option can be used to reduce the setback. Provide a setback dimension for the carport on the next submittal. 2. COMMENT: Depending on the proposed setback of the Carport will determine if a Variance process or Design Development Option will be required. If the setback is at least one foot from the east property line a Design Development Option can be applied for. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdf A Design Development Option must be applied for and approved before this permit can be approved by Zoning. For more information about the DDO process contact Wyatt Berger at wyatt.berger@tucsonaz.gov Georgia Pennington at Georgia.Pennington@tucsonaz.gov 3. COMMENT: Aerial imagery shows two structures located in the northwest corner of the property, that are not shown on the site plan. Show the structures on the site plan, and provide dimensions, setbacks, and heights for each. If either structure is over 200 square feet add it to the lot coverage calculation. 4. COMMENT: Provide individual callouts for the square footage of the Existing House, ADU, and Driveways for the Lot Coverage Calculation. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised residential building permit along with a detailed response letter, which states how all Zoning Review Section comments were addressed. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions about this transmittal, please contact Nathan Herrera at Nathan.Herrera@TucsonAZ.gov. |
||
| 04/12/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |