Permit Number: TC-RES-0424-02086
Parcel: 133434310

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0424-02086
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2024 Residential Building APPROVED
04/10/2024 Fire New Construction NOT REQUIRED
05/07/2024 Site Engineering NOT REQUIRED
05/08/2024 Site Landscape NOT REQUIRED
05/09/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/09/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0424-02086
945 N LA SALLE AV. – R-2
Detached Ramada (1st Review)

TRANSMITTAL DATE: May 9, 2024

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof.

The minimum setback to interior property lines are the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

1. Based on a wall height of 10’-11” the required perimeter yard setback from the proposed ramada to the west property line is 7’-4”, proposed setback is 6’-0”.
Per UDC Article 6.6.2.D An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s). To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________
The setback waiver will need to be signed by a Board Member of the Coronado Ridge Homeowners Assn.

2. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/09/2024 PDSD Application Completeness Express REVIEW COMPLETED