07/18/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/25/2024 | Residential Building | REQUIRES RESUBMIT | 1. The roof structure may not extend to a point closer than 3 feet from the adjoining (neighboring) property line without fire rated protection for fire spread. Show the materials for achieving prescriptive one-hour fire-resistive construction in compliance with IBC Table 721.1(2). 2. Field welding requires a special inspection request form for review with the permit plans, R109.2. Provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections |
||
07/10/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0424-01956 4409-4411 East Waverly Street – R-2 Carport (CE-VIO0823-04885) (2nd Review) TRANSMITTAL DATE: July 10, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 5. Per UDC 6.4.5.C.1.a, for residential development, the minimum required front street perimeter yard is twenty feet as measured from the street property line. The proposed front street perimeter yard is 2' as measured from the south lot line. A Design Development Option (DDO) is required to reduce the front street perimeter yard from 20' to 2'. 6. Interior perimeter yards are based on a measurement from the design grade elevation to the highest point of an exterior building wall (see UDC 6.4.5-B and Figure 6.4.5-A). Based on a wall height of 10', the required side perimeter yard is 6’-8” as measured from the west lot line. The proposed side perimeter yard is 1’. A DDO is also required to reduce the side perimeter yard from 6'-8" to 1'. Zoning acknowledges a DDO application has been submitted with this review. Zoning cannot approve TC-RES-0424-01956 until the DDO process is complete. Contact Georgia.Pennington@tucsonaz.gov or Mark.Castro@tucsonaz.gov if you have questions about the DDO process. 7. The removal of the street curb cut requires Department of Transportation and Mobility (DTM) approval. A separate right-of-way permit has not yet been applied for per the Property Research Online website. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised plan set as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
07/18/2024 | Zoning Modifications - DDO | REQUIRES RESUBMIT | The DDO application has been accepted for processing. Please allow 4-6 weeks for this process. If the application is approved, please include in your required comment response letter the following information: DDO case number, the request, and condition(s) of approval. If you have questions, please email Mark.Castro@tucsonaz.gov | ||