Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/12/2023 | Site Zoning | APPROVED | |||
05/25/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/25/2023 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0423-04834 (11453 E RINCON RANGE DR TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Code reference, 2018 International Residential Code (IRC). Electrical Plans (Loft addition): 1. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2, E3901.2.2 item 3. This may require a floor mounted receptacle outlet within 18” of the window wall, R3901.2.3. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
05/03/2023 | PDSD Application Completeness | REVIEW COMPLETED | |||
05/04/2023 | Site Engineering | REVIEW COMPLETED |