Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0423-04810
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/25/2023 | Residential Building | APPROVED | |||
| 05/03/2023 | Site Landscape | NOT REQUIRED | |||
| 05/26/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/16/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-RES-0423-04810 9580 E. Palm Tree Dr. – R-1 Front Porch (1st Review) TRANSMITTAL DATE: May 16, 2023 Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 1. Provide a dimension from the centerline of Palm Tree Dr. to the face of curb and from face of curb to the north street property line. The distance from centerline to curb should be 15’-0”, and from curb to property line should be 10’-0”. 2. The north arrow shown on for the plot plan is not correct. 3. Provide the legal description, “TWENTY-NINE PALMS LOT 38 EXC S15' THEREOF” on the plot plan. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. 4. The minimum setback to the front street perimeter property line is twenty (20) feet measured from the street property line (UDC 6.4.5.C.1.a). For porch type structures this distance is measured form the post supporting the porch, (UDC 6.4.5.B.2). As setback dimensions from the post were not provided zoning is assuming the post is 1’-2” from the roof overhang for a proposed setback dimension of 17’-2”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov |
||
| 05/26/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | The Zoning Review Section has indicated that Design Development Option (DDO) is required to allow the construction to remain with a reduced front street perimeter yard setback. Ensure comment 1 is addressed prior to submittal of a DDO application. The DDO application and its requirements can be found in this link: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. Submit a completed application with your resubmittal under permit number TC-RES-0423-04810. Should you have questions regarding this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at (520)837-4951. |
||
| 05/05/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 05/03/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 05/04/2023 | Site Engineering | REVIEW COMPLETED |