Permit Number: TC-RES-0423-04727
Parcel: 136212680

Address:
7231 E TAMARA DR

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0423-04727
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/23/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/23/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0423-04727 (7231 E TAMARA DR TUCSON, AZ 85730)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken.
Code reference, 2018 International Residential Code (IRC).

1. Provide a detail view of the rafters connection to the existing wall. Show rafter to wall connection using (H2.5) ties having a resistance to uplift of not less than 365 pounds, R802.11.1. (City of Tucson Amended). See https://www.tucsonaz.gov/files/pdsd/pdfs/Porch_Sample.pdf page 3 of 3, detail 1.
2. Provide Gluelamb manufacturer details and specifications sheet showing it is rated for the given span. 6”x8” x 18’ gluelamb is undersized by StruCalc calculations. R301.1.
3. Provide a detail view of beam attachment to columns. Show all connection hardware type. See https://www.tucsonaz.gov/files/pdsd/pdfs/Porch_Sample.pdf page 3 of 3, detail 1 and page 4.
4. Notate all roof slopes appropriate with selected material, R901.1. (Minimum allowable slope for Built-up roof is ¼” per foot, R905.9.1. Minimum allowable slope for roll roofing is 1” per foot, R905.5.2. Or provide manufacturer specification sheet).
5. Notate and specify a complete roofing system: Roof sheathing, size (1/2” OSB) and method of installation (moisture barrier, flashing, etc.), R905.
6. Show the proposed fixture as full cut-off style, FCO, or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/12/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0423-04727
7231 E. Tamara Dr. – R-1
Expand Front Porch (1st Review)

TRANSMITTAL DATE: May 12, 2023

Provided a detail comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. The plot plan shall include:
a. The plot plan shall be drawn at an engineer scale, i.e. 1” = 10’ or 1” = 20’.
b. The lot coverage calculation shall meet the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements.
c. Provide the property dimensions on the plot plan.
d. Provide the legal description, “VALLEY VIEW EAST NO 3 LOT 35” on the plot plan.
e. Provide a dimension from the centerline of Tamara Dr. to the face of curb and from the face of curb to the south property line. The distance from centerline to curb is 19’ and from curb to property line is 11’.
f. The 21’ front setback is not correct and should be 20’.
g. Provide a setback from the southeast corner of the proposed porch to the east property line.

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.

2. Provide a height dimension from design grade to the top of beam so that setback requirements can be verified.

3. Based on aerial photos there is a structure that shows up some time after 2018 located near the northwest corner of the rear yard. Show this structure on the plan. Zoning was not able to find approved permit/compliance review documents for this structure. Either provide approved permit/compliance review documents or include it in this permit. It does not appear that this structure meets perimeter yard setback requirements to the southwest property line. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). At a minimum a neighbors setback waiver will be required if this structure does not meet setbacks. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s):
My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan.

Signature: _____________________________

Date: _________________________________

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov