Permit Number: TC-RES-0423-04694
Parcel: 124051010

Address:
728 E 4TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0423-04694
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/31/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
05/31/2023 Historic REQUIRES RESUBMIT Property is a contributing resource to the West University Historic Preservation Zone and requires review and approval. Submit required documents noted in Historic & Special Districts informational handout (https://www.tucsonaz.gov/files/pdsd/forms/Special_Districts_Application_Instructions.pdf) under the Historic sub-record. Once we receive a complete submittal, we will docket the project for review with West University Historic Zone Advisory Board (WUHZAB) and the Plans Review Subcommittee (PRS).
Additionally, please include information on the window manufacturer and the stucco texture. Indicate how the house will be prepared for stucco (i.e. foam board and chicken wire or another method).
05/23/2023 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0423-04694 (728 E 4TH ST TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken.
Code reference, 2018 International Residential Code (IRC).

1. Plans show changes in window sizes, thus complete framing plans are required, R301.1.
2. Provide a header schedule for supporting the roof consistent with Table 502.5(1) & R602.7(1). (Windows 4, 7, 9, 17, 18, 20).
3. Show compliance with R310 providing egress from bedrooms with minimum net clear opening area of 5 SQ FT. Also, show the minimum net clear opening dimension of 24” height and 20” width, and maximum sill height of 44”. (Windows 20 or 4, and 18 or 17. A 4’ high double hung window will not meet the net clear opening height of 24”.).

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/16/2023 Site Zoning REQUIRES RESUBMIT FROM: Iman Monshizadeh
PDSD Zoning Review Section
PROJECT: TC-RES-0423-04694 / Replacement of windows
Plot Plan Review (1st Review)
728 S 4Th Av / HR-2
TRANSMITTAL DATE: 05/16/2023

1. The property is located in a historic zone (HR-2). Historic approval is required prior to zoning approval.

Resubmittal instructions: https://www.tucsonaz.gov/files/pdsd/pdfs/Resubmittals.pdf

For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov
05/01/2023 PDSD Application Completeness REVIEW COMPLETED