Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-RES-0423-04631
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/28/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/28/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Please provide total load of house for review and we need the total length to the farthest appliance. Refence G2413.4.1 G2415.17.3 (404.17.3) Tracer. A yellow insulated copper tracer wire or other approved conductor, or a product specifically designed for that purpose, shall be installed adjacent to underground nonmetallic piping. Access shall be provided to the tracer wire or the tracer wire shall terminate above ground at each end of the nonmetallic piping. The tracer wire size shall be not less than 18 AWG and the insulation type shall be suitable for direct burial. |
||
04/21/2023 | PDSD Application Completeness | REVIEW COMPLETED |