Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2
Permit Number - TC-RES-0423-04610
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/01/2023 | Residential Building | APPROVED | G2415.17.3 (404.17.3) Tracer. A yellow insulated copper tracer wire or other approved conductor, or a product specifically designed for that purpose, shall be installed adjacent to underground nonmetallic piping. Access shall be provided to the tracer wire or the tracer wire shall terminate above ground at each end of the nonmetallic piping. The tracer wire size shall be not less than 18 AWG and the insulation type shall be suitable for direct burial. |
||
| 05/03/2023 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 05/01/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |