Permit Number: TC-RES-0423-04556
Parcel: 127020580

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0423-04556
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2023 Residential Building APPROVED
05/18/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/10/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0423-04556
5131 E. Hawthorne Pl. – R-1
Room & Porch Add (1st Review)

TRANSMITTAL DATE: May 10, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, to include but not limited to:
a. The plot plan shall be drawn at an engineering scale, i.e. 1” = 10’, 1” = 20’.
b. Provide a lot coverage calculation the meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements.
c. Provide the zoning for all adjacent properties
d. Show the location of all utilities on the plot plan.
e. Provide a dimension from the centerline of Hawthorne Pl to the face of curb and from face of curb to the south property line.

2. Based on aerial photos there is a carport type structure that shows up along the east side of the existing dwelling sometime after 2006. Zoning was not able to find approved permit documents for this structure. Either provide approved permit documents or include this structure in the permit.

3. The setbacks shown under “ZONING REQUIREMENTS” are not correct. Front street perimeter yard setback requirement is 20’-0”, side and rear is 6’ or 2/3 the height of the exterior wall.

4. It doesn’t appear that the existing structure is drawn correct. Based on aerial photos the structure mentioned above is much closer than 10’ to the east property line.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov
04/27/2023 PDSD Application Completeness Express REVIEW COMPLETED
05/03/2023 Site Engineering REVIEW COMPLETED
05/03/2023 Site Landscape REVIEW COMPLETED