Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0423-04541
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/26/2024 | Site Zoning | APPROVED | |||
| 06/05/2024 | Fire New Construction | NOT REQUIRED | |||
| 07/01/2024 | Site Engineering | NOT REQUIRED | |||
| 07/01/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/17/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0423-04541 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating an awareness of minimum building code compliance for passing all progress inspections. Provide a response letter on separate file with submitting the updated construction plan set. Consider using a design professional if unfamiliar with construction documentation. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed. Place page numbers on each sheet of the construction plan set. Provide a clear and concise construction plan set. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Provide a site plan showing an address at each dwelling unit. Clarify with a Pima County assigned address for the front and back unit. 2. Provide a site plan showing utilities for the dwellings, R106.1.1. Show the location of all utility lines from property line to building(s) along with required alterations. FLOOR PLAN: 1. Provide a floor plan showing each proposed room with labeled function and dimensions. Show door locations and window sizes with type identified as XO or SH. Bedrooms require code compliance for egress, R310. STRUCTURAL PLANS: 1. Individual dwelling units require separation with a 1-hour fire-resistance rated assembly without openings, R302.3. Provide a detail or notation showing compliance with 703.3 of the 2018 IBC. PLUMBING PLANS: 1. Provide protection of (indoor rated) equipment located outdoors with an exterior rated enclosure, G2406.3. 2. Show the water heater capacity (size) and type (gas or electrical), P2801.1. MECHANICAL PLANS: 1. Provide demand calculations in accordance with Manual J standards for replaced units, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, E3404.12. 2. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. Provide proposed wiring details showing code compliant device locations and circuit sizes. 3. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity, R314.3. 4. Show receptacle outlets at wall spaces 2’ or more with no wall point (exclude door openings) more than 6’ from a receptacle outlet, E3901.2. 5. Show at least one wall-switch-controlled lighting outlet providing illumination on the exterior side of each egress door having grade level access R3903.3. 6. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 06/04/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |