Permit Number: TC-RES-0423-04508
Parcel: 122152880

Address:
3241 E SENECA ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.4

Permit Number - TC-RES-0423-04508
Review Name: RESIDENTIAL NEW DWELLING v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/28/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/28/2024 Site Engineering REQUIRES RESUBMIT Site Engineering cannot approve the permit until the associated floodplain use permit, TE-FPU-0124-00031, has been approved. See the comments on that permit.

Lianne Evans
lianne.evans@tucsonaz.gov
02/23/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0423-04508
3241 E. Seneca St. – R-1
Metal Fence (2nd Review)

TRANSMITTAL DATE: November 17, 2023

Please resubmit revised drawings detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence with an ADU is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, 8, & 9 and 6.6.3.

This plan has been reviewed for compliance with the Unified Development Code (UDC). The UDC can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code.

1. The provided detail shows the “BACK FENCE: CORRUGATED” as being “3X3 Posts / 24” in the ground / 160 lb Concrete / 6.5’ Tall”. The plan submitted on the 1st review stated that the back fence was “6’ tall”. The fence as shown on the provided detail is required to meet the 6’-0” perimeter yard setback or the area above 6’-0” must demonstrate that one of the requirements listed below is met.
Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .)
a. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron;
b. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall;
c. A greater height is required through the rezoning process or the special exception land use process; or,
d. A greater height is required by a specific UDC standard.

2. Either demonstrate that one of the exceptions above can be met, lower the fence height, or apply for a Design Development Option (DDO) to allow the 7’-0” fence height within a perimeter yard. The DDO must submitted and approved prior to approval of this plan. DDO requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

3. The plan submittal shall include the detail and aerial photo show the location of the proposed fence.



If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.