Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0423-04474
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/10/2023 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0423-04474 (5343 S WEDGEWOOD PL TUCSON, AZ 85746) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Code reference, 2018 International Residential Code (IRC). 1. Page PV 3, #8 wire is undersized for the combined current. NEC 690.8(B). a. 690.8(8) (1) 75 degree rating, 50A < 125%*41.14A. #8 is too small. b. 690.8(8) (2) 75 degree rating, 50A*.91 > 41.14A. c. Choose the greater wire size required from the calculations above. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 04/17/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |