Review Date Reviewer's Name Type of Review Description Status Comments
05/15/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/15/2023 Residential Building REQUIRES RESUBMIT TC-RES-0423-04457

PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319.

Show the upper level gross square footage including the three foot bathroom extension, R106.1.1.

GENERAL COMMENTS :

1. All plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 .
a. Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3. Model plans should show four typical south facing roof surfaces.
b. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. Update breaker space to the last panel space.
c. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. Include a gray drain-line discharge of all second story bathing fixtures through an exterior-wall drop for future gravity distribution. Include an aliened purple colored 2” or 3” vertical drop to a cleanout cap 2’ above grade. The homeowner may perform system alteration for future gray water usage. Add the appropriate detail found at the web site: https://www.tucsonaz.gov/pdsd/water-energy-conservation
2. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240 volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space or show the distance from transit or a bike boulevard as not greater than a quarter-mile.

SITE PLAN:

1. Show the location and size of buildings, utility meters and gas, water, electric and sewer lines from property line to building, R106.1.1. Show sizes of lines requiring alteration.
2. Show a street address for each dwelling on the site plan, R319.

PLUMBING PLANS:

1. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate yard pipe bypassing the existing dwelling and the water meter size.

MECHANICAL PLANS:

1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation, or controlled exhaust with a calculated airflow rate, R303.4; N1103.6 & M1505.4. Show the system and appropriate flow rate setting on the plans. A two or three bedroom dwelling of 1501 – 3000 SF requires a 60 CFM continuous setting.
2. Provide demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J and duct systems sized in accordance with Manual D. Notate if the mechanical plans if system calculations will be provided by deferred submittal.

ELECTRICAL PLANS:

1. TEP may require the service panel for the property at the closest building to the service transformer. A service line change or a new meter location must be coordinated with TEP for approval. Show an underground feeder from a new metered service panel to the more distant dwelling.
2. Update the Riser Diagram for the close dwelling and the feeder size to the detached dwelling panel, NEC 225.30 and E3403. Show a Riser Diagram providing service disconnect of either dwelling without service disruption of the other dwelling.
3. Provide the Electric Vehicle Supply Equipment 40 ampere 240 volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2.
4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
(520) 837-4912 PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
04/17/2023 Site Landscape REQUIRES RESUBMIT Provide an NPPP or NPPO waiver (located here: https://cms3.tucsonaz.gov/files/pdsd/forms/NPPOapp.pdf) with your resubmittal.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
05/01/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: TC-RES-0423-04457
625 North Treat Avenue – R-1
2nd dwelling unit (1st Review)

TRANSMITTAL DATE: May 1, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

The site is in the R-1 zone (UDC 4.7.8). A second dwelling unit is permitted in the R-1 zone, subject to use-specific standards 4.9.7.B.1-.9 and .11.

1. Demonstrate compliance with use-specific standard 4.9.7.B.7 by providing a floor plan of the existing residence. For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom. For all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. An existing covered residential parking area may be used. Show the location of the required motor vehicle parking spaces with your next submittal.

The term “bedroom” as defined in UDC 11.4.3 includes all of the following: 1) Any room that is designated as a bedroom; 2) Any enclosed room that has a minimum area of 60 square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms; and 3) Any room designated as a bedroom for the purpose of any other code requirement.

2. Remove the porches and second stories from the total lot coverage calculation as roofed areas, open on at least one side that are not used for utilities, maintenance, laundry, storage, or motor vehicle parking, are not included within lot coverage (UDC 6.4.3.C.1.a). Additionally, only the ground level of buildings is included within total lot coverage (UDC 6.4.3.B.3.a).

3. Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required side and rear yard setbacks are six feet or 2/3 the height of the proposed wall, whichever is greater, measured from the property line.

As the elevation drawings do not provide dimensions from design grade to the highest point of the proposed walls, Zoning added an additional 0’-4” to the dimensions based on the foundation information provided. Based on a wall height of approximately 19’-4”, the required setback from the west property line to the proposed building wall is 12’-11”. The proposed setback is 8’-4”.

DDO approval is required to reduce the above setback. The DDO application and requirements may be retrieved from: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. The completed application shall be submitted as a PDF under assigned permit number TC-RES-0423-04457. Contact Georgia.Pennington@tucsonaz.gov should you have questions regarding the DDO process.

If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
05/01/2023 Zoning Modifications - DDO REQUIRES RESUBMIT DATE: 5/1/23
FROM: Georgia Pennington, Planner

COMMENTS:

1. Address all Site Zoning comments.

2. Zoning has identified an item that requires a Design Development Option (DDO). The DDO application and requirements may be retrieved from: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. The completed application shall be submitted as a PDF under assigned permit number TC-RES-0423-04457.

If you have questions about this transmittal, please email me at georgia.pennington@tucsonaz.gov.
04/17/2023 Fire New Construction REVIEW COMPLETED
04/15/2023 PDSD Application Completeness Express REVIEW COMPLETED
05/03/2023 Site Engineering REVIEW COMPLETED