Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0423-04234
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2023 | Site Zoning | APPROVED | |||
| 05/08/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/08/2023 | Residential Building | REQUIRES RESUBMIT | Any structure placed in the 3-foot fire separation distance from the neighboring property line requires not less than one-hour fire-resistive construction for reducing fire spread across the property line, R302.1. Fire rated materials are found in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. Show a compliant fire barrier on the plan or provide a minimum of 3 feet between the property line and structure. | ||
| 04/10/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 04/20/2023 | Site Engineering | REVIEW COMPLETED | |||
| 04/17/2023 | Site Landscape | REVIEW COMPLETED |