Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0326-01496
Parcel: 138100260

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-0326-01496
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/09/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/09/2026 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Previous comments were not addressed:
Please show or describe how Whole home surge protection will be installed in the panel and re submit. Code references from the 2024 IRC & 2023 NEC below.
If you have any questions, you can reach me at Zane.aouane@tucsonaz.gov
E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3.
E3606.5.1 Location: the SPD shall be an integral part of the service equipment or shall be located immediately adjacent, if not located at each next-level distribution equipment downstream toward the load.
E3606.5.2 Type: the SPD shall be a Type 1 or Type 2 SPD.
E3606.5.3 Replacement: Where service equipment is replaced, all of the requirements of this section shall apply.
04/09/2026 PDSD Application Completeness Express REVIEW COMPLETED