Permit Number: TC-RES-0326-01469
Parcel: 13728003A

Review Status: Approved

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0326-01469
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
04/01/2026 Residential Building - Standard APPROVED Panel upgrade comments

Please show or describe how Whole home surge protection will be installed in the panel and re submit. Code references from the 2024 IRC & 2023 NEC below.

If you have any questions, you can reach me at jorge.ruiz@tucsonaz.gov

E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3.

E3606.5.1 Location: the SPD shall be an integral part of the service equipment or shall be located immediately adjacent, if not located at each next-level distribution equipment downstream toward the load.

E3606.5.2 Type: the SPD shall be a Type 1 or Type 2 SPD.

E3606.5.3 Replacement: Where service equipment is replaced, all of the requirements of this section shall apply.



2023 NEC 230.67 mandates whole-house surge protection (SPD) for services supplying dwelling units, dormitories, hotel/motel guest rooms, and patient rooms in nursing homes, requiring a Type 1 or Type 2 SPD, often built-in or next to the service, with a minimum 10kA nominal discharge current rating, and also applies to service replacement, expanding on the 2020 code's requirement for just dwelling units.
03/27/2026 Residential Engineering NOT REQUIRED
04/09/2026 Residential Zoning NOT REQUIRED Interior Remodel ONLY
04/09/2026 Bldg Permits - Post Review Express REVIEW COMPLETED
03/27/2026 PDSD Application Completeness Express REVIEW COMPLETED