Permit Review Detail
Review Status: In Review
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-0326-01342
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Design Review - Standard | PENDING ASSIGNMENT | |||
| N/A | Residential Building - Standard | PENDING ASSIGNMENT | Please review the comments below and re submit. 1. Smoke detectors are on the electrical legend but not shown on the plans, please show where ALL smoke detectors are in the home. 2. Please use architectural details applicable to the scope of work and please ensure details are clear to read. Page A3. 3. Please show whole home surge protection. E3606.5 Surge protection: all services supplying dwelling units shall be provided with a surge-protective device (SPD) installed in accordance with Sections E3606.5.1 through E3606.5.3. 4. Attic ventilation is not clear. |
||
| 03/31/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0326-01342 – Residential Building 1225 E Edison St, Tucson, AZ 85719 Residential Addition/Alteration (1st Review) TRANSMITTAL DATE: March 31st, 2026 This site is located in the NR-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The minimum perimeter yard setback in the NR-1 zone is 5’ per the recent Middle Housing Code Amendment, not 6' as is indicated on the plan. The proposed pantry addition is indicated as having a setback of 4’8”. As the pantry is attached to the primary dwelling, a neighbor waiver will not be sufficient to waive the required setback. A Design Development Option (DDO) will be required. Consider adjusting the design to meet the 5’ setback. If the design cannot be adjusted to meet the 5’ setback, please submit a DDO application under the Zoning Modification sub-record that has been created. For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For additional questions regarding DDOs, contact Mark Castro at Mark.Castro@tucsonaz.gov. 2. (Comment) This site is located in the NR-1 zone. NPZ Design Review may be required. Zoning cannot approve this permit until the associated NPZ review has been approved. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 03/18/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |