Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-0326-01173
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/22/2026 | Residential Building - Standard | APPROVED | |||
| 04/22/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/22/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Erick Bieber Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0326-01173 – Residential Building 4025 E 2nd St, Tucson, AZ 85711 Residential Addition/Alteration (2nd Review) TRANSMITTAL DATE: April 22nd, 2026 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. (Comment) The provided site plan is still not sufficient. Please refer to the following link for site plan examples and a full list of what is required: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Site-Plan-Examples 2. (Comment) Ensure drawings are drawn to an engineering scale, i.e. 1” = 10’-0’. The provided drawings of the property and buildings are not to scale. 3. (Comment) Provide setback measurements from the shade structures to all applicable property lines. 4. (Comment) The property line dimensions are correctly identified as 60’ by 135’, they do not need to be indicated as approximate. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Erick.Bieber@tucsonaz.gov |
||
| 04/14/2026 | Addressing Validation | REVIEW COMPLETED | |||
| 04/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | For questions, email PDSD-Permits@tucsonaz.gov. Your Owner Builder Affidavit (OBA) requires resubmit because you need to initial both boxes with your first and last initial where it says "PLEASE READ AND INITIAL THE FOLLOWING:" instead of marking with an X. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |