Permit Number: TC-RES-0326-01106
Parcel: 133040330

Address:
9350 E LEE ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-0326-01106
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2026 Residential Zoning APPROVED
03/23/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/23/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0326-01106
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2024 International Residential Code and 2018 International Energy Conservation Code. The 2024 International Energy Conservation Code takes effect July 1st. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2024 IRC code compliance.

Place the 2024 IRC reference code on the cover sheet and G1.01.

Provide a separate response letter addressing each comment with location of change on the plans.

GENERAL:

1. The design, construction and installation of private residence elevators installed within a residential unit or providing access to one individual dwelling unit shall conform to ASME A17.1/CSA B44, Section 5.3. Provide the requirement note on the plans.
2. The elevator installation requires a completed special inspection request form for review with the permit plans, R109.2. Obtain an inspector and provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections

PLANS:

1. Remove the deferred truss submittal note from the cover sheet.
2. Clarify the existing and proposed items, R106.1.1. Update the proposed mechanical enclosure on sheet A2.01.
3. Note the maximum opening between the elevator and guard as 4” on sheet A2.02, R321.1.3.

ELECTRICAL PLANS:

1. Interior alterations require the installation of smoke alarms in existing bedrooms, R310.2.2. Provide notation if the smoke alarms exist or are proposed.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Building Safety
03/05/2026 PDSD Application Completeness Express REVIEW COMPLETED For questions: PDSD-Permits@tucsonaz.gov
A separate State of Arizona permit is required for an elevator.
Here is the link the their website for the elevator permit; https://www.azica.gov/forms/adosh-elevator-application-permit-install-or-alter-elevator-form