Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0325-01673
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 05/07/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/30/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01673 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Note the 2018 IRC reference on the plans. The plans may require additional changes for showing 2018 IRC compliance of construction performed without a permit. Provide plans showing compliance with the 2018 IRC. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the location of utility meters and electric lines from property line to buildings, R106.1.1. Identify the utility lines requiring upgrade or replacement. 2. An overhead service conductor may not pass over the proposed building without an 8-foot clearance above the roof, E3604.2.1. PLANS: 1. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3. SECTIONS - DETAILS: 1. Provide a wall section detail with (#4 rebar) reinforced 12” x 12” reinforced foundations for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. PLUMBING PLANS: 1. Show any proposed changes. MECHANICAL PLANS: 1. Show any proposed changes. ELECTRICAL PLANS: 1. Show any proposed changes. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 05/07/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Zoning Review Section PROJECT: TC-RES-0325-01673 – Residential Building – 16 x 36 Shed 2240 S Placita Perlozzo Tucson, AZ 85748 (RX-1 Zoning) Building Plan Review – 1st Review TRANSMITTAL DATE: May 07, 2025 This site is in the RX-1 zone (UDC 4.7.6). A single-family residence is a permitted use in this zone (Table 4.8-1) subject to Use Specific Standards 4.9.7.B.6, .8, & .9. Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers zoning, use(s), legal description, adjacent properties, setbacks (building or wall heights), dimensional standards, property permitting history, density (units/lot size), and lot calculation (enclosed building and structure, parking, and driveway versus overall lot size) requirements. All code references are to the Tucson, AZ Unified Development Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct the following plan and elevation sheets, as noted in the comments below, along with a detailed response letter indicating responses to the review comments. PLANS: 1.COMMENT: Refer to the Residential Building Reviewers comments regarding the need to communicate utility locations. See this hyperlink for an example of our plot (site) plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf 2. COMMENT: Provide missing zoning classifications for lots 338 and 339 directly across the street (also like the plot plan depicts). 3. COMMENT: After reviewing the property documentation history in PRO, zoning could not verify any permit documentation for the existing storage container. As this structure was located in the southernmost setback, a neighbor sign off would be required. The adjacent owner’s waiver statement must be added to the site plan. The following statement can be used. My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ 4. COMMENT: Should you be unsuccessful in your attempt to retrieve this waiver we offer our Design Development Option which affords someone to attempt to seek relief from the setback requirements. This information is linked here: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3 4. COMMENT: Provide dimensions of this container structure as well as the dimensions to the property line, the square footage and height. 5. COMMENT: Update the lot coverage table to include the updated square footage for the proposed shed and white container storage structure along the south property line. 6. COMMENT: Additional comments may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards. Please contact the zoning reviewer if you have any questions: Jeffrey W Cassidy jeffrey.cassidy@tucsonaz.gov City of Tucson Site Zoning and Planning Reviewer Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 04/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |