Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0325-01604
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/28/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/25/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/20/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01604 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN: 1. Show the location of the electric service panel, R106.1.1. Identify the overhead utility lines requiring upgrade or replacement. PLUMBING PLANS: 1. Show the water heater rating if proposed as a new unit, P2801.1. Show as electric or gas. Provide a gas pipe or circuit sized for the demand. 2. Show each gas pipe segment sized in conformance with Table G2413.4(1). Existing gas pipes may require upgrading with this system alteration. 3. Show hot water pipe with minimum R-3 insulation, N1103.4.2. Show compliance with the maximum length of hot water piping shall not exceed 50’, IPC607.2. MECHANICAL PLANS: 1. Show the casita HVAC system size accordance with R303.9, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Show a single feeder or branch circuit to the accessory (detached casita) building, NEC 225.30. 2. Show a smoke alarm in the casita with an electrical circuit, R314.3. 3. Designate the circuit numbers consistent with the panel schedule, R106.1.1. 4. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. 5. Show a wall switch controlled light for the casita outdoor entrances or exits, E3903.3. OUTDOOR LIGHTING CODE 1. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 05/28/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0325-01604 515 S SANTA RITA AV. Unit: 2 – R-2 Remodel SFR (Unit 2) and Sleeping Quarters(1st Review) TRANSMITTAL DATE: May 28, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Provide all property dimensions of the site plan. 2. Based on Construction Plan I-536 sheet 9, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-536, the dimension shown from curb to the west property line is not correct. Review the plan and provide the correct dimension. 3. The lot coverage calculation is not correct. Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are not included in the calculation and per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage. 4. The setback requirements listed for the “FRONT (SOUTH)” is not correct. The south property line does not front on a street so is not considered a front setback. 5. The setback requirements listed for the ”SIDE (WEST) is not correct. The west is the front street and should meet the requirements of UDC Article 6.4.5.C.1.a. 6. The carport shown in the southeast corner of the parcel shows up sometime after 2006. Zoning was not able to find approved permit documents for this carport. Either 1) provide approved permit documents, 2) include the carport in the permit, or 3) show the carport to be removed from site. 7. There is what appears to be a shade type structure along the north side of existing primary residence that appears sometime after 2016. Zoning was not able to find approved permit documents for this structure. Either 1) provide approved permit documents, 2) include the structure in the permit, or 3) show the structure to be removed from site. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/25/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |