Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0325-01526
Parcel: 118041710

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.2

Permit Number - TC-RES-0325-01526
Review Name: RESIDENTIAL SOLAR v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/13/2025 Light Residential Building Review (OIP) - Standard REQUIRES RESUBMIT Permit Review TC-RES-0325-01526 (1814 S SAN ANTONIO DR TUCSON, AZ 85713). Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC).
1. After review of the permit I do not see the comment that you have provided with your response to what changes you have made. Please double check to make sure that it was for this permit.
2. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability for 115 MPH, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems
3. When applying for a permit to place new equipment on existing code-compliant roofs, an allowance shall be provided for equipment weighing a maximum of 4 psf and load per attachment point of 45lbs or less. https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Development%20Services/Building/Equipment%20on%20roofs%20.pdf
Provide calculations showing total roof equipment weight is a maximum per attachment point of 45lbs or less and distributed weight is 4psf or less. R324.4.1.1

Building_official@tucsonaz.gov
05/28/2025 Site Engineering - Standard REQUIRES RESUBMIT TC-RES-0325-01526
1814 S SAN ANTONIO DR

Site engineering comments are as follows:
1. This project lies within a recognized floodplain and requires a Floodplain Use Permit (FUP). One has been applied for (TE-FPU-0425-00163), however, it requires a cost estimate of materials and labor from your contractor in the form of a pdf attachment. Please have separate lines for the cost of materials, cost of labor, and any administrative fees or warranties. Thank you.
Ryan Insalaco – ryan.insalaco@tucsonaz.gov
04/23/2025 PDSD Application Completeness Express REVIEW COMPLETED