Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - TC-RES-0325-01524
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/29/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01524 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes for detached shade structures greater than 200 square feet in area. Provide a response letter on separate file when submitting the updated construction plan set. Provide a clear and concise construction plan set. Review the sample drawings for a free standing structure which are similar to the Porch Sample. Sample plans are available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Indicate the location of the proposed buildings and the existing electrical line, R106.1.1. Show the utility lines requiring relocation. 2. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2) or provide Pima County processed utility easement preventing construction within 3 feet of the structure on the neighboring property. STRUCTURAL PLANS: 1. Show the size and location of each support footing, R106.1.1. A center post may be required for supporting undersized beams. 2. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. 3. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. Prefab structures have engineered plans available from the supplier which are included with the submitted site plan. SECTIONS - DETAILS: 1 Show wood posts in contact with soil or concrete as pressure treated, R317.1. 2 Provide structural roof sheathing size and fastening in compliance with Table R602.3 (1). 3 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. ELECTRICAL PLANS: 1. Show any electrical alterations. 2. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. Check with TEP customer service for service line options. https://www.tep.com/electric-service-requirements If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 05/10/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TC-RES-0325-01524 10722 E AVENIDA HACIENDA Site engineering comments are as follows: 1. This project is within a regulated floodplain as defined by the subdivision plat and requires a Floodplain Use Permit (FUP). Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home Ryan Insalaco – ryan.insalaco@tucsonaz.gov |
||
| 05/07/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0325-01524 10722 E AVENIDA HACIEND. – RX-1 Two metal shade structures: 12' x 16' and 12' x 20' (1st Review) TRANSMITTAL DATE: May 7, 2025 Provide a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example. 2. The provided description states “Two metal shade structures: 12' x 16' and 12' x 20'” but there is only one (1) 12’ x 20’ structure shown on the plan. 3. Once the above comments are addressed additional comments maybe forth coming. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 04/09/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |