Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.2
Permit Number - TC-RES-0325-01492
Review Name: RESIDENTIAL FENCE/WALL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2025 | Residential Building | APPROVED | |||
| 04/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/15/2025 | ROW Engineering Review | REQUIRES RESUBMIT | Existing masonry fence/wall encroaches in the pedestrian area. A four-foot wide walk area must be kept free between property line and curb. See Technical Standards Manual Section 10-01.2.7.C (Sidewalk Areas) | ||
| 04/16/2025 | Site Engineering | REQUIRES RESUBMIT | TC-RES-0325-01492 2611 E FLORENCE DR This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” NOTE: For fences built in the floodplain, flood venting holes in the fence must be provided at grade. For . Solid or Panel fences in floodplains require 6 inches of clearance between the bottom of the fence and grade level, or an 8-inch flood vent must be present every 12 inches. For brick walls, an open brick must be present every other brick at grade. Chris Arrington chris.arrington@tucsonaz.gov |
||
| 04/15/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0325-01492 2611 E Florence Drive Tucson, AZ 85716 Unpermitted Pony Wall (1st Review) TRANSMITTAL DATE: 4/15/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Code violation CE-VIO1024-04060 states the wall is built in the right of way and obstructing pedestrian access. Site zoning is unable to approve this permit until the code violation is abated. 2. Comment: Additional comments may be forthcoming depending on plans submitted and responses to zoning review comments. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 03/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |