Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0325-01490
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/28/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01490 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Show the current code reference on the plans. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. GENERAL COMMENTS : 1. Provide a complete construction plan set showing 2018 IRC compliance, R106.1.1. SITE PLAN: 1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1. 2. Each dwelling building requires a street address and a separate permit, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. PLANS: 1. Provide complete roof framing plans. Show size, spacing and span of all framing members, trusses, joists, rafters, headers, R301.1. SECTIONS - DETAILS: 1. Provide a wall section detail with reinforced foundations for anchoring exterior framed walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground (R317.1 item 5). The weep screed may extend with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. 3. Clarify the placement of ceiling/roof insulation for determining the need for attic ventilation, R806. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2 or an unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. PLUMBING PLANS: 1. Provide a complete plumbing plan. MECHANICAL PLANS: 1. Provide a complete mechanical plan with HVAC sized in accordance with Manual D. ELECTRICAL PLANS: 1. Provide a complete electrical plan. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Show full cutoff fixtures were located within 25 feet from the property line OLC 401.3.3. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services |
||
| 04/30/2025 | Site Engineering - Standard | REQUIRES RESUBMIT | TC-RES-0325-01490 4473 E PIMA ST 1. This project is in a local regulatory floodplain (FEMA Zone X shaded - 100-year depths up to 1ft.) and requires a floodplain use permit with elevation certificate. Due to limited flood data at this location, you have two options: a) Assume 1 ft. for the base flood depth and add 1 ft. state required freeboard - elevate the structure so that the finished flood elevation (FFE) is 2 feet above existing grade. b) Provide a hydrology report that determines the exact 100-year flood depth at the site and establishes the required FFE. The plans must clearly state the proposed FFE, either in relation to existing grade (i.e. FFE to be 2 feet above existing grade) or in ft NAVD88. Submit these revised plans for the floodplain use permit as well as the resubmittal for this building permit Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” . Chris Arrington chris.arrington@tucsonaz.gov |
||
| 04/30/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0325-01490 4473 E Pima Street Tucson, AZ 85712 Rebuilding structure on northwest corner of property (1st Review) TRANSMITTAL DATE: 4/30/2025 This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The provided site plan is missing several key components, and it is unclear which area is included in the scope of work as there are multiple buildings at this location. Site zoning was unable to conduct a complete review with the included document. The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference. 2. Comment: The property dimensions are incorrectly labeled. The north property dimension is 90’. Please update. https://gis.pima.gov/maps/subdiv/select.cfm?null=&bkpg=06028. 3. Comment: Please include the surrounding zoning classification as noted in the sample site plan. This property is surrounded by R-2 zoning. 4. Comment: Please include the legal description as noted in the sample site plan. The legal description is “PALOMA LOT 11 & E2 LOT 12 EXC S10’ & EXC SPNDRL BLK 1”. 5. Comment: Please draw, label, and dimension the ½ Right of Way from centerline to face of curb and from face of curb to the property line along both Pima Street and Belvedere Avenue. 6. Comment: Please include lot coverage calculations as noted in the sample site plan. 7. Comment: Clearly show the vehicular use area on your site plan and include this calculation in your lot coverage calculations. 8. Comment: Please include elevations measured from design grade of any proposed buildings in this permit to ensure the minimum setbacks are met. For side and rear yards, the minimum required setback in the R-2 zone is 6’ or 2/3 Height of the proposed exterior wall as measured from design grade. A Design Development Option (DDO) will be required if the minimum setbacks cannot be met however, I am unsure which building is included in the proposed scope of work. DDO comments may be forthcoming depending on updated plans submitted. 9. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 04/03/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |