| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/22/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01487 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. PLUMBING PLANS: 1. Show each gas pipe segment sized in conformance with Table G2413.4(1). Clarify gas pipe sizes for either two water heaters on the plan or the water heater and range shown on the gas demand schedule. A 14’ length of ¾” pipe at the 200,000 BTU demand branch is undersized. ELECTRICAL PLANS: 1. The two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. Remove circuit A:18 from the laundry countertops. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 04/25/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-RES-0325-01487 2131 N Frannea Drive Tucson, AZ 85712 Renovate SFR (1st Review) TRANSMITTAL DATE: 4/25/2025 This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: Please include the legal description which should read “Rainbow Vista Estates Lot 88”. 2. Comment: Please include the lot coverage calculations on your site plan. If needed, please refer to the sample plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. 3. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 03/28/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |