Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-0325-01474
Parcel: 112061220

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING REVISION v.1

Permit Number - TC-RES-0325-01474
Review Name: RESIDENTIAL NEW DWELLING REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2025 Residential Zoning APPROVED
11/06/2025 Residential Engineering NOT REQUIRED
11/10/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
11/10/2025 Residential Building Standard REQUIRES RESUBMIT Provide a complete roof framing plan with a ridge member sized with appropriate load carrying capacity. Show the ridge structural member as a full sized beam with appropriate load bearing rating when the roof pitch is less than 3” to 12”, R802.3. Update detail #1 on sheet S2.0 with an appropriate beam or provide a registrant stamp for the non-prescriptive design.
10/30/2025 PDSD Application Completeness Express REVIEW COMPLETED