Permit Number: TC-RES-0325-01356
Parcel: 113050420

Address:
3508 N OLSEN AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0325-01356
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2025 Site Engineering - Standard NOT REQUIRED
04/25/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/22/2025 Residential Building - Standard REQUIRES RESUBMIT ACTIVITY NO. TC-RES-0325-01356
ADDRESS/PARCEL: (3508 N OLSEN AV)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Review will not proceed without the response letter.

1.Provide full structural calculations
2.Provide detailed wind load calculations
3. Ensure all section keynotes refer to correct details (Elevation view connection between Colum and beam 01/S2 is referring to the incorrect detail)
4. Provide electrical plans for lighting
5. Provide structural calculations for optional spread footing
6. Submit SIC for field welding

Should you have any questions about these comments, I can be reached at Zane.Aouane@tucsonaz.gov
04/24/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review

PROJECT: TC-RES-0325-01356
3508 N OLSEN AV. – RX-2
Detached Carport (1st Review)

TRANSMITTAL DATE: March 3, 2025

Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example, to include but not limited to:
a. Provide the owners name on the plot plan.
b. Label the zoning of this parcel and all adjacent parcels.
c. Provide the legal description on the plot plan.
d. Provide a dimension from the center line of Olsen to the face of curb, and from face of curb to the property line.
e. The property dimensions are not correct.
f. Provide perimeter yard setbacks from the proposed carport to all applicable property lines.

2. Per UDC Article 6.4.5.C.1.a For single-family and duplex development , the minimum required front street perimeter yard is 20 feet measured from the street property line. Per UDC Article 6.4.5.D.3.a Shade structures or carports may project up to ten feet into required perimeter yards. It does not appear that the 10’ street perimeter yard setback is met and a Design Development Option (DDO) maybe required. As perimeter yard setbacks were not provided Zoning cannot provide the required Design Development Option (DDO) comments for submittal of the DDO.

3. Per UDC Table 6.3-1.A the minimum setback is twenty feet facing each interior property line. It does not appear that the 20’ perimeter yard setback is met to the south property line and a Design Development Option (DDO) maybe required. As perimeter yard setbacks were not provided Zoning cannot provide the required Design Development Option (DDO) comments for submittal of the DDO.

4. Per UDC Article 6.6.3.C Detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for shade structures or carports not over 400 square feet in floor area. The detached carport as shown on the plan will require a Board of Adjustment for Variance.

5. Provide a height dimension from design grade to the highest point of the flat roof, UDC Article 6.4.4.A. Per UDC Article 6.6.3.D accessory structures, except for accessory dwelling units , shall not exceed 12 feet in height, unless attached to a principal structure.

If you elect to go the Board of Adjustment route the reduced setbacks can be included in the process.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov.

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”.

Additional comments may be forthcoming once the comments are addressed correctly.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/25/2025 Zoning Modifications - DDO - Standard REQUIRES RESUBMIT The DDO application cannot be accepted for the following reasons:
1. Based on Site Zoning review comments, the detached carport in the front yard will require a Board of Adjustment variance approval.
2. Refer to Site Zoning review comments 2 and 3. Reduced setbacks request should be added to the Board of Adjustment variance application.

Next step, address Site Zoning review comments and resubmit the plans with a comment response letter addressing all comments. Additional comments will be forthcoming after the resubmittal. If you have questions on this transmittal, email Mark.Castro@tucsonaz.gov
03/26/2025 PDSD Application Completeness Express REVIEW COMPLETED