Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0325-01331
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/23/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/25/2025 | Site Zoning - Standard | NOT REQUIRED | |||
| 04/25/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/25/2025 | Addressing Validation | REQUIRES RESUBMIT | Provide a unit number as there are units attached to this address. For questions you may contact building_official@tucsonaz.gov | ||
| 04/23/2025 | Historic - Standard | REQUIRES RESUBMIT | Staff has opened and completed initial review under the TC-RES-0325-01331 and opened the Historic sub-record. Please submit all the same materials under the Historic sub-record in a single compressed pdf file to apply for a SD#. Review fees will be invoiced for payment. Attached is a link on how to get to the sub-record. https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf If you have any questions, contact Michael.Taku@tucsonaz.gov |
||
| 04/21/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01331 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. SITE PLAN: 1. Show the dwelling unit numbers for each building with a kitchen, R106.1.1. PLANS: 1. Show the sleeping room egress opening size with R310 compliance. PLUMBING PLANS: 1. Show each gas pipe segment sized in conformance with Table G2413.4(1). Existing gas pipes may require upgrading with this system alteration. MECHANICAL PLANS: 1. Show the HVAC system with supply to each habitable room, M1401.3 & M1601.1. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity with an electrical circuit, R314.3. 2. Show the location of the panelboard, E3404.12 & E3405.2. 3. Show two or more 2O AMP GFCI small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3. (in addition to circuit #7) If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 03/25/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |