Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0325-01291
Parcel: 11106016C

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0325-01291
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2025 Site Engineering - Standard NOT REQUIRED
04/29/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/28/2025 Addressing Validation REQUIRES RESUBMIT An Accessory Dwelling Unit (ADU) requires to be separately addressed and the location does not appear to have unit C attached to the address, please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to verify and or add the units. NOTE: A resubmittal and a submission for an address change request is required to properly update the location record of this permit. For questions: Building_Official@tucsonaz.gov
04/22/2025 Residential Building - Standard REQUIRES RESUBMIT TC-RES-0325-01291
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Each dwelling unit with kitchen requires a separate Pima County assigned street address after Zoning approval, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. https://www.pima.gov/1010/Addressing-Frequently-Asked-Questions

An impact fee payment is required for an ADU or second dwelling at the time of permit payment.

This permit application is processed for an ADU not the replaced HVAC in the duplex which requires a separate permit for each addressed unit.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLUMBING PLANS:

1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate water meter size for the additional demand.
2. Show the water heater rating, P2801.1.

MECHANICAL PLANS:

1. Show the HVAC system size in accordance with M1401.3, M1601.1.

ELECTRICAL PLANS:

1. Show the location of the smoke alarm, R314.
2. Show two or more (dedicated) 2O AMP small appliance circuits at the kitchen countertop receptacle outlets;, E3703.2 and E3901.3.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Both standard and high-density R-38 batt insulation requires a space greater than provided with 2” x 8” framing, N1102.1. Identify the product that provides the intended minimum R-30 for a dwelling under 500 SF, R806.5.

If you have any questions, please contact:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/pdsd
04/29/2025 Site Zoning - Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Zoning Review Section

PROJECT: TC-RES-0325-01291 – Residential Building – Renovate ADU without Permit
2930 N Winstel Bl Tucson, AZ 85716 (R-3 Zoning)
Building Plan Review – 1st Review

TRANSMITTAL DATE: April 29, 2025

This site is located in the R-3 zone (Unified Development Code (UDC) Article 4.7.12). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Development package to be submitted and approved prior to approval of the building permit.

1. COMMENT: This address appears to be part of a larger site (for example, the vehicular access into the site is through the adjacent property to the east). Due to the site consisting of 3 or more units, the use is considered Multifamily, and a Development Package meeting the requirements of Administrative Manual 2-06 will be required..
2. COMMENT: Per Unified Development Code (UDC) Section 3.3.3.G, a development package is required to be submitted and approved prior to the approval of a residential building permit for an expansion of gross floor area (GFA).
3. The requirements for a development package can be accessed at the following link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Development-Package
4. This residential building permit will be compared against the approved development package prior to its approval.

If you have any questions about this transmittal, please contact Jeffrey W. Cassidy at jeffrey.cassidy@tucsonaz.gov.
03/28/2025 PDSD Application Completeness Express REVIEW COMPLETED