Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0325-01231
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2025 | Site Zoning - Standard | APPROVED | |||
| 04/14/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/14/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/14/2025 | Addressing Validation | REQUIRES RESUBMIT | The plans submitted shows to be for Accessory Dwelling Unit. The address location does not have ADU attached to the address. Unit # will have to be confirmed and assigned to Permit Application and on Plans prior to issuance. Once Zoning approves the 2nd unit contact Pima County Addressing to resolve issue Addressing@pima.gov or 520-724-9512. Please submit a comment letter and Plans (with unit #). | ||
| 04/07/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01231 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. An impact fee payment is required for an ADU or second dwelling at the time of permit payment. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. PLUMBING PLANS: 1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate yard pipe bypassing the existing dwelling and show an appropriate water meter size for the additional demand. ELECTRICAL PLANS: 1. Provide a minimum service conductor rating of #3 copper 75 degree C for the 100 AMP feeder, E3602.1 & E3603.1. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 03/14/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |