Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0325-01183
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/04/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/04/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/06/2025 | Addressing Validation | REQUIRES RESUBMIT | Unable to process. The address included on the plan set does not indicate a unit number. Please clarify which unit will be having the room addition and include the unit number on all pages of the plan set. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf For questions: building_official@tucsonaz.gov. |
||
| 04/01/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0325-01183 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits SITE PLAN: 1. Show the address of each dwelling on the site plan, R106.1.1. 2. Show the square footage of the proposed living space, R106.1.1. PLANS: 1. Show the proposed functional name of each existing adjacent room, R106.1.1. Existing bedroom #2 with a removed egress window requires a different function, R310. A room may not function as a bedroom without direct egress to the exterior. 2. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s sealed plan set for manufactured trusses, R301.1.3. The 2x8 rafters may not span 15 feet. 3. Clarify if the 8” firewall is currently 10’6” high or requires additional height to an existing wall IRC, R301.1. Adding height requires rebar placement shown on the plans. SECTIONS - DETAILS: 1. Provide a wall section detail showing 12” x 12” (#4 rebar) continuous reinforced foundation for anchoring exterior framed (insulated) walls with pressure treated sills including ½” anchor bolts with 7” embedment, R403.1.6. 2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. PLUMBING PLANS: 1. The Tucson Water Department limits flow rates for the water meter size in compliance with P2903.7. Show an appropriate yard pipe and water meter size for the total demand. 2. Show plumbing vent sizes and locations (VTR) within acceptable distances from traps, P3105.1. (1 ½”-6’, 2”-8’, 3”-12’). MECHANICAL PLANS: 1. Provide the Manual J report referenced at note H, M1401.3, M1601.1. ELECTRICAL PLANS: 1. Show a smoke alarm in the bedroom and outside the doorway in the immediate vicinity, R314.3. 2. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 04/01/2025 | Site Zoning - Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0325-01183 1565 E 25TH ST Unit: 1 – R-2 Bedroom, bath, laundry and 1/2 bath addition (1st Review) TRANSMITTAL DATE: April 1, 2025 Provide a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Provide a setback dimension from the proposed addition to the west property line. COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the wall meets the eave of the roof. As height dimensions from design grade were not provided The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. Based on a wall height of 11’-0” the required perimeter yard setback from the detached shed to the west property line is 7’-4”, Proposed setback is was not provided. If the proposed setback is 1’-0” or more, a Design Development Option (DDO) can be used to reduce the setback. If the proposed setback is less than 1’-0” a Board of Adjustment for Variance is required to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 03/06/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |