08/04/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/31/2025 ROW Engineering Review REQUIRES RESUBMIT New fence looks like it is encroaching public Right-of-Way. Plans do not show 25' radius corner for alley. Sight visibility triangle is not shown on plans, Department of Transportation and Mobility (DTM) does not allow fences in the street/alley. See code Sec. 25-46. Obstructing streets prohibited.
07/29/2025 Site Engineering REQUIRES RESUBMIT Permit: TC-RES-0325-01128
Location: 2008 N Bell AV
Review Date: 7/29/2025
Site Engineering Comments:
1. The sight visibility triangle comment has not been addressed. Please draw and show the sight visibility triangle regarding the T-intersection created by N Bell Av and the alley way to properly show that lines of sight are not obscured. This can be found within the Technical Standards manual 10-01.5.0. A proper Example will be emailed to show a better representation of what is required.
2. On the site plan, delineate the right of way lines to ensure no encroachment within the ROW
Delineate Right of way lines on the site plan to ensure no encroachment into the ROW

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
07/28/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0325-01128
2008 N Bell Ave. – R-2
Site fence (4th Review)

TRANSMITTAL DATE: July 28, 2025

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six feet, proposed height of the site fence is 7’-8”. A Design Development Option (DDO) must be submitted and approved to allow the proposed 7’-8” fence height. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3 . If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. Zoning acknowledges that the DDO was submitted but until approved Zoning cannot approve this permit.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
08/04/2025 Zoning Modifications - DDO REQUIRES RESUBMIT The DDO application has been uploaded to TP-MOD-0825-000033. Refer to this sub-record for the DDO status and progress. Please allow 4-6 weeks for this process. If the application is approved, please include with your required comment response letter a copy of the DDO decision letter when you resubmit under your permit TC-RES-0325-01128. If you have questions, please email Georgia.Pennington@tucsonaz.gov