Permit Number: TC-RES-0325-01128
Parcel: 12201043A

Address:
2008 N Bell AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL FENCE/WALL v.4

Permit Number - TC-RES-0325-01128
Review Name: RESIDENTIAL FENCE/WALL v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/06/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/06/2025 Residential Building REQUIRES RESUBMIT The Document submitted does not include a structural engineer or architect's stamp. The anchoring system and stem wall needs to be reviewed and approved by a Arizona registrant to ensure the wall meets seismic loads and resistance of a wall over 7ft. Any other walls in your area over 7ft without these requirements are not in compliance with code. These requirements are enforced to ensure the safety of people and property. If you plan to submit engineer approved documents, please wait to re submit until you can provide these documents.

Should you have any questions about these comments, I can be reached at Zane.Aouane@tucsonaz.gov
05/06/2025 Site Engineering REQUIRES RESUBMIT TC-RES-0325-01128
2008 N Bell AV

Your parcel is located on one of the corners of a T- intersection created by N Bell Av and an alley. Per the Technical Standard Manual (TSM) 10-01.5.0 “Clear lines of sight will be maintained along all streets and driveways to assure the safety of motorists and pedestrians. Lines of sight will not be obscured between 30 inches and six feet through a triangular area adjacent to a driveway, a PAAL, an alley, or a street, where such access ways intersect with another street in a T-configuration.”

Please delineate the sight visibility triangle on the site plan. See TSM 10-01.5.3 and Figure 16 SVT.

Note: The stem side of the triangle would be in the alley. The longer 185’ side of the triangle would be along N Bell Av.
Line of sight must be unobstructed between 30" & 6' within the triangle when the 2 sides of the triangle are connected.

https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-12455
https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-12539

Chris Arrington
chris.arrington@tucsonaz.gov
05/06/2025 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0325-01128
2008 N Bell Ave. – R-2
Site fence (3rd Review)

TRANSMITTAL DATE: May 6, 2025

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. The submitted plot plan is not usable. Also it does not appear that the proposed wall height if provided. Fence height is Measured from design grade to the highest point of the fence along the side of the fence that faces adjacent properties, UDC Article 6.6.4

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
04/22/2025 PDSD Application Completeness Express REVIEW COMPLETED