Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SIMPLE REVIEW v.1
Permit Number - TC-RES-0324-01850
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/28/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/28/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0324-01850 (7401 E STELLA RD TUCSON, AZ 85730) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). 1. Provide a complete gas piping template showing the connection from the meter to all gas appliances, G2401.1, R301.1: Include pipe size, type and length. Provide appliance demands, G2413.4.1. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_handout_2018_irc_2019.2.4.pdf >>> Missing the pipe type and length measurements of each segment. 2. Size the pipe based on the length from the meter to the farthest attached appliance and max total Branch demand of all attached appliances using Table G2413.4(1) (Metallic Pipe), Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. 3. For the ¾ inch flex line, provide the manufacturer’s specifications showing the product type and EHD or flow rating Use Table G2413.4(5) for Corrugated Stainless Steel Tubing. Note: The length is measured from the meter to the furthest attached appliance for all sizing, G2413.4.1. 4. Clarify if the gas range is a new appliance, converting from electric to gas. 5. The addition of a new appliance requires that the existing system be enlarged to meet the total demand, or a new dedicated line is required for the range, G2412.3, G2412.4. 6. The existing system is undersized for the given demand of 200,00 BTUh, assuming existing piping is Metallic Pipe, see Table G2413.4(1). Calculated length is 88 feet. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 03/28/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |