Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0324-01727
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2024 | Fire New Construction | NOT REQUIRED | |||
| 04/19/2024 | Site Engineering | NOT REQUIRED | |||
| 05/07/2024 | Site Landscape | NOT REQUIRED | |||
| 05/07/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/11/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0324-01727 (339 S CHERRY AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC). Electrical Review: 1. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside the doorway in the immediate vicinity. 2. Show a GFCI receptacle outlet on the same level within 25’ of exterior HVAC equipment, E3901.12. 3. Clothes Washer GFCI: receptacles require readily accessible protection, E3902.9. Show the cloths washer receptacle as GFCI protected and readily accessible. Structural Review: 4. Provide the manufacturer’s specification sheets for the TJI 560 and TJI 230 rafters showing their rating for ~20’ span, R106.1.1, 802.1.8. Include manufacturer’s detail page for TJI outriggers detail on sheet A-02 section-5, R106.1.1. Mechanical Review: 5. Provide HVAC demand calculations in accordance with Manual J/S/D standards, M1401.3, M1601.1. Systems shall be sized in accordance with Manual S based on building loads calculated in accordance with Manual J. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 04/22/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0324-01727 339 S CHERRY AV . – R-2 Bedroom / Bathroom Addition (1st Review) TRANSMITTAL DATE: April 22, 2024 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). 1. The lot coverage calculation is not correct. Review UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, and provide a correct lot coverage calculation. Per UDC Article 6.4.3.C.1.a Roofed areas, porches, open on at least one side are not included in the calculation. And perUDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage. 2. The sidewalk show along Cherry Ave. is not shown correctly. Per Paving plan U-2009-044, found at: https://maps-and-records.tucsonaz.gov/construction-plans/details/U-2009-044 the face of wedge curb is located 16’ west of the west property line with the sidewalk directly adjacent to the back of wedge curb. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 03/22/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |