Review Date Reviewer's Name Type of Review Description Status Comments
08/11/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/11/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0324-01716 - CE-VIO0324-01021
9625 E COLETTE ST. – R-1
Detached 3 Car Carport, Patio Roof Extension, Detached Metal Shade Structure & Detached Metal Shed – built without permit (5th Review)

TRANSMITTAL DATE: August 11, 2025

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Until the DDO is approved Zoning cannot approve this permit. Per UDC Article 6.4.5.C.1.a For single-family and duplex development , the minimum required front street perimeter yard is 20 feet measured from the street property line, based on the current drawings the proposed street permit yard setback is 1’-6”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback.

2. Until the DDO is approved Zoning cannot approve this permit. The metal shed shown along the east property line does not meet the required six (6) feet, or two-thirds (2/3) the height of the structure’s wall, greater of the two, facing each interior property line (Table 6.3-2.A). Based on a height of 7’-0” the required perimeter yard setback from the shed to the east property line is 6’-0”, proposed setback is 3’-0”. The reduced setback for this shed can be dealt with in one of two ways, 1) Provide a neighbors setback waiver, see below. 2) Include the shed setback in you DDO request.

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/22/2025 Zoning Modifications - DDO - Standard REQUIRES RESUBMIT Refer to TP-MOD-0725-000018 for status on the DDO application. At this time, there is an application fee due. Once payment has been made, the DDO process can continue. This process does involve a notice that is mailed to property owners within 100' of your property lines and to your neighborhood association (if here is one that is registered with the City) that describes the project and what is being requested. There is a 10-day comment period where people may submit comments to our department regarding the request. After a decision is issued, there is a two-week appeal period. Zoning cannot approve the plans until the appeal period is over and no appeal has been filed. This process takes approximately 6 weeks. If you have questions regarding this transmittal, e-mail Mark.Castro@tucsonaz.gov
07/16/2025 PDSD Application Completeness Express REVIEW COMPLETED