Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0324-01716
Parcel: 133410710

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.9

Permit Number - TC-RES-0324-01716
Review Name: RESIDENTIAL NEW DWELLING v.9
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/01/2025 Residential Building APPROVED
04/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/21/2025 Site Zoning - Standard REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-RES-0324-01716 - CE-VIO0324-01021
9625 E COLETTE ST. – R-1
Detached 3 Car Carport, Patio Roof Extension, Detached Metal Shade Structure & Detached Metal Shed – built without permit (4th Review)

TRANSMITTAL DATE: April 21, 2025

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Zoning acknowledges that you intend to apply for a Design Development Option (DDO), but did not see the required documents with this submittal, see the link below.

2. Until the DDO is approved Zoning cannot approve this permit. Per UDC Article 6.4.5.C.1.a For single-family and duplex development , the minimum required front street perimeter yard is 20 feet measured from the street property line, based on the current drawings the proposed street permit yard setback is 1’-6”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback.

3. Until the DDO is approved Zoning cannot approve this permit. The metal shed shown along the east property line does not meet the required six (6) feet, or two-thirds (2/3) the height of the structure’s wall, greater of the two, facing each interior property line (Table 6.3-2.A). Based on a height of 7’-0” the required perimeter yard setback from the shed to the east property line is 6’-0”, proposed setback is 3’-0”. The reduced setback for this shed can be dealt with in one of two ways, 1) Provide a neighbors setback waiver, see below. 2) Include the shed setback in you DDO request.

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov.

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/20/2025 PDSD Application Completeness Express REVIEW COMPLETED