Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.6
Permit Number - TC-RES-0324-01716
Review Name: RESIDENTIAL NEW DWELLING v.6
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/18/2024 | Site Engineering | NOT REQUIRED | |||
10/21/2024 | Site Landscape | NOT REQUIRED | |||
11/27/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/30/2024 | Residential Building | REQUIRES RESUBMIT | Permit Review TC-RES-0324-01716 (9625 E COLETTE ST TUCSON, AZ 85748) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). Carport Review 1. The latest plans for the carport do not match the previous plans as approved by Residential Building review. Why was page 8 and 9 added back into the plans? 2. Any structure placed in the 3-foot fire separation distance from the neighboring property line requires not less than one-hour fire-resistive construction for reducing fire spread across the property line, R302.1(City of Tucson Amended). Fire rated materials are found in IBC Table 721.1(2), Items 15-1.1 to 16-1.3. 3. Show the (carport roof) structure with one-hour fire-resistive wall construction parallel with the neighboring property line in compliance with IBC Table 721.1(2) or provide a clear 3’ fire separation distance between the property line and the structure. This construction or separation is required from ground to roof and from end to end of the roof which resists fire spread across the property line. 4. Fire separation wall requires a continuous footing. Provide a one-hour fire-resistive wall detail from foundation to roof. 5. Roof projections extending into the 3-foot fire separation distance to the neighboring property line require not less than one-hour fire-resistive construction on the underside, R302.1 (City of Tucson Amended). The fire protected overhang may not extend closer than 24” from the property line. The open sided carport cannot be closer than 24” to the property line on the West side without fire-resistive construction. 6. Limit cantilevered overhang to 24”, or provide engineered design, R802.7.1. See pages 8. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
11/27/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-0324-01716 - CE-VIO0324-01021 9625 E COLETTE ST. – R-1 Detached 3 Car Carport, Patio Roof Extension, Detached Metal Shade Structure & Detached Metal Shed – built without permit (2nd Review) TRANSMITTAL DATE: August 22, 2024 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example, to include but not limited to: a. This comment was not addressed. The setback dimensions shall be provided on the plot plan. Provide perimeter yard setback dimensions from the posts supporting the proposed carport to the west property line, UDC Article 6.4.5.B.2. b. This comment was not addressed. The street property line is 1’ north of the sidewalk. The setback dimension shown from southeast post of the proposed detached carport is shown to the back of sidewalk not the property line and should be to the property line. 2. This comment was not addressed. Per UDC Article 6.4.5.C.1.a For single-family and duplex development , the minimum required front street perimeter yard is 20 feet measured from the street property line, based on the current drawings the proposed street permit yard setback is 1’-6”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback. 3. This comment was not addressed. The metal shed shown along the east property line does not meet the required six (6) feet, or two-thirds (2/3) the height of the structure’s wall, greater of the two, facing each interior property line (Table 6.3-2.A). Based on a height of 7’-0” the required perimeter yard setback from the shed to the east property line is 6’-0”, proposed setback is 3’-0”. The reduced setback for this shed can be dealt with in one of two ways, 1) Provide a neighbors setback waiver, see below. 2) Include the shed setback in you DDO request. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. To secure this neighbor setback waiver the following statement must be provided on the plot plan and be signed and dated by the adjacent property owner(s): My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. Can I get Zoning DDO added to TC-RES-0324-01716 please. |
||
10/18/2024 | PDSD Application Completeness | REVIEW COMPLETED |