Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0324-01671
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/22/2024 | Site Zoning | APPROVED | |||
| 04/19/2024 | Site Engineering | NOT REQUIRED | |||
| 04/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/08/2024 | Residential Building | REQUIRES RESUBMIT | 1. Show an individual water heater for each building, P2801.1. Clarify the location at the building being supplied service as a carport is not show on the site plan. 2. The building shall be supplied by a single service, NEC 230.2 & E3601.2. Show all loads assigned to panel B in the load calculation and upgrade the feeder size as appropriate. 3. Provide a panelboard clear working space of 30” wide x 36” deep for panel B, E3405.2. |
||
| 03/21/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |