Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2024 Residential Building APPROVED Permit Review TC-RES-0324-01638 (7172 S SHIPMANS TALE CT TUCSON, AZ 85756)
Approved
>>> Corrected via phone call and edits.
1. Provide rafter sizes and spacing in compliance with Table R802.4. 2x8 rafters @ 24oc are undersized for the measured span at 15’ 4”.
2. Show wood beam seats with 1/2" clearance from masonry on top, end & sides, R317.1 item 4.
3. Provide the Beam anchor product manufacturer/name.
04/19/2024 Site Zoning APPROVED
03/26/2024 Fire New Construction NOT REQUIRED
04/19/2024 Site Engineering NOT REQUIRED
03/21/2024 Site Landscape NOT REQUIRED
04/19/2024 Bldg Permits - Post Review Express REVIEW COMPLETED
03/20/2024 PDSD Application Completeness Express REVIEW COMPLETED