Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL SOLAR v.1
Permit Number - TC-RES-0324-01586
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/15/2024 | Site Engineering | NOT REQUIRED | |||
04/17/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
04/17/2024 | Historic | REQUIRES RESUBMIT | Property is listed as a contributing resource to the XXXX Historic Preservation Zone. Review is required through the Historic Zone Advisory Board and the Plans Review Subcommittee. Please provide required documents listed in the Historic & Special Districts informational handout (https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf) under the Minor Review. Staff has reviewed the submittal and has the following comments: (1) Provide a brief narrative of the scope of work (2) Provide a colored photo of the main house. (3) Elevations of the existing buildings on site showing where the panels are to be located. (4) Provide color photos showing precedent within the Development Zone. Once the Historic submittal is complete, please submit it under the Historic sub-record. See link below for steps on resubmitting. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf If you have any questions, contact Michael Taku at Michael.Taku@tucsonaz.gov. |
||
03/25/2024 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-0324-01586 (620 S 3RD AV TUCSON, AZ 85701) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. For wind uplift use 115 mph in 3sec gust, Table R301.2(1). https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/building-code/2018_-_irc_amendments.pdf 2. Provide a lag-bolt connection up-lift calculation demonstrating the wind load supporting capability, or provide an engineer’s calculation, and sealed design, R301.1, R324.4. An IRC PV roof uplift calculator (XLS) is available on Pima County’s website. https://www.pima.gov/1069/Solar-Wind-Systems Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
04/15/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0324-01586 620 South 3rd Avenue – HR-3 Roof-mounted solar (1st Review) TRANSMITTAL DATE: April 15, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. The following comments are relative to an application for Historic Review (UDC 5.8.8). 1. The site is in the Armory Park Historic Preservation Zone (HPZ). The proposal affects the exterior appearance of the building and requires Historic review and approval. The Historic application instructions can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf. Zoning cannot approve TC-RES-0324-01586 until the Historic review process has been approved. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
03/18/2024 | PDSD Application Completeness | REVIEW COMPLETED |