Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-0324-01549
Parcel: 116022910

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-0324-01549
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2024 Fire New Construction NOT REQUIRED
05/14/2024 Site Zoning NOT REQUIRED
05/16/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
05/16/2024 Residential Building REQUIRES RESUBMIT Permit Review TC-RES-0324-01549 (2870 W PLACITA DE JUAN TUCSON, AZ 85745)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

1. Provide an updated panel schedule for the existing Main Service Panel (Page 3). Show the circuits being added to.
2. Add the following notes to the updated Page 3:

Protect extended branch circuits with combination type arc-fault circuit interrupters, or an AFCI type receptacle at the first outlet on the branch circuit, E3902.17.

Protection of all interior 15A & 20A circuits serving outlet locations (except bathrooms) including receptacles, lights and smoke detectors require combination type arc-fault circuit interrupters, E3902.16.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
05/07/2024 PDSD Application Completeness REVIEW COMPLETED