Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0324-01532
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/15/2024 | Fire New Construction | NOT REQUIRED | |||
| 04/19/2024 | Site Landscape | NOT REQUIRED | |||
| 04/19/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/26/2024 | Residential Building | REQUIRES RESUBMIT | TC-RES-0324-01532 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. STRUCTURAL PLANS: 1. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. SECTIONS - DETAILS: 1 Show roof sheathing and fastening in compliance with Table R602.3 (1) or note open joist without sheathing loads. 2 Identify all fasteners for wind loading compliance. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. If you have any questions, please contact: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 04/11/2024 | Site Engineering | REQUIRES RESUBMIT | This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.) Please start a new FUP at our permit application web page: https://tdc-online.tucsonaz.gov/#/home NOTE: Documentation of a cost estimate from your contractor will be required if this project involves any reconstruction, repair, rehabilitation, structurally connected addition, or other improvement of an existing structure (including TIs and solar). Construction of separate builds/new structures does not require a cost estimate to be provided. Construction of new buildings require elevation one foot above the base flood elevation, which may require that the foundation of the building be raised as much as two feet above the existing elevation onsite. Storage buildings with no utilities may be wet floodproofed using flood vents. For all new construction buildings, two elevation certificates must be filled out by a registered land surveyor and submitted to the City, one before the foundation is poured and one after construction is completed. Instructions: 1. Navigate into the current project in the “My Work” tab. Within the permit, navigate to the “Sub-Records” tab and click “Apply” on the Floodplain Use Permit Sub-Record 2. Locations -> Confirm the location is accurate to the project. Click “Next” 3. Type -> Fill in the “Square Feet” and “Valuation” boxes with the project area and a contractor-provided cost estimate (See note above: for new structures, input 0). Click “Next” 4. Contacts -> Confirm contacts and add any additional contacts if applicable. Click “Next” 5. More Info -> This will be filled in by the engineer assigned to your case, Click “Next” 6. Attachments -> Please attach the project plan, supporting documentation for the cost estimate (if applicable), and a drainage/hydrology report (if applicable). Click “Next” 7. Signature -> Read the statement and type your name. Sign your name below (You may Enable Type Signature to have the software sign for you.) Click “Next” 8. Review and Submit -> Review all information to ensure accuracy. Click “Submit” Contact Lianne Evans at lianne.evans@tucsonaz.gov if you have any questions about the FUP. |
||
| 04/08/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: Wyatt Berger Lead Planner PROJECT: TC-RES-0324-01532 2932 North Jackson Drive – R-1 Carport addition (1st Review) TRANSMITTAL DATE: April 8, 2024 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. 1. Provide a site plan that meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf. At a minimum, the plot plan shall include the following information: a. Show the square footage of the lot, the existing dwelling, any additions to the dwelling, accessory structures, and total under roof area; b. Provide a lot coverage calculation (the area of the site occupied by buildings, storage areas, and vehicular use areas); and c. Show a dimension from the centerline of Jackson Drive to the curb location, and a dimension from the curb location to the front street lot line (refer to paving plan I-622: https://maps-and-records.tucsonaz.gov/construction-plans/details/I-622). 2. The lot dimensions on the site plan are incorrect and should be listed as 75 feet in width and 120 feet in depth per the Shaheen Estates subdivision plat. 3. Show the 7.5-foot-wide utility easement along the south lot line as depicted on the Shaheen Estates subdivision plat: https://maps-and-records.tucsonaz.gov/subdivisions/details/MP-12006&. 4. Indicate the setback measured from the north property line to the proposed construction. Per Tucson Unified Development Code (UDC) Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required perimeter yard is six feet or 2/3 the height of the proposed building wall, whichever is greater, measured from the interior property line. A vertical structural member such as a post or column is considered a wall for applying perimeter yard requirements (UDC 6.4.5.B.2). Based on a post height of 10’-11”, the required perimeter yard measured from the north property line is 7’-3”. 5. Per UDC 6.6.3.C, detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for shade structures or carports no over 400 square feet in floor area. The proposed carport is detached from the principal structure and exceeds 400 square feet in floor area. A variance granted by the Board of Adjustment is required to exceed this requirement, unless the size of the carport is decreased, or the carport is attached to the principal structure. Contact Mark.Castro@tucsonaz.gov if you have questions about the variance process. If you have any questions about this transmittal, contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951. |
||
| 03/15/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |